{"id":3512,"date":"2026-10-13T11:55:00","date_gmt":"2026-10-13T03:55:00","guid":{"rendered":"https:\/\/www.polive3d.com\/?p=3512"},"modified":"2026-11-09T15:20:12","modified_gmt":"2026-11-09T07:20:12","slug":"pp-%e6%89%93%e5%8d%b0%e4%bb%b6%e9%98%b2%e6%b0%b4%e5%90%97%ef%bc%9fpp-%e5%9c%a8%e6%bd%ae%e6%b9%bf%e5%92%8c%e6%b0%b4%e7%8e%af%e5%a2%83%e4%b8%ad%e7%9a%84%e8%a1%a8%e7%8e%b0","status":"publish","type":"post","link":"https:\/\/www.polive3d.com\/en\/pp-%e6%89%93%e5%8d%b0%e4%bb%b6%e9%98%b2%e6%b0%b4%e5%90%97%ef%bc%9fpp-%e5%9c%a8%e6%bd%ae%e6%b9%bf%e5%92%8c%e6%b0%b4%e7%8e%af%e5%a2%83%e4%b8%ad%e7%9a%84%e8%a1%a8%e7%8e%b0\/","title":{"rendered":"Are PP Prints Waterproof? How PP Performs in Wet and Water Environments"},"content":{"rendered":"<h2 class=\"wp-block-heading\"><strong>Are PP Prints Waterproof? How PP Performs in Wet and Water Environments<\/strong><strong><\/strong><\/h2>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<p class=\"wp-block-paragraph\">PP itself has very low water absorption, so its dimensional stability in humid and watery environments is generally good.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">But this does not mean that all PP 3D printed parts are naturally &#8220;waterproof.&#8221;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">For FDM printed parts,<strong>the water resistance of the material itself and the leak-proof performance of the finished part are two different issues.<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Even if the PP material itself does not easily absorb water, if the following exist during printing:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Micro-gaps between layers<\/li>\n\n\n\n<li>Under-extrusion<\/li>\n\n\n\n<li>Insufficient wall thickness<\/li>\n\n\n\n<li>Pores on top or bottom surfaces<\/li>\n\n\n\n<li>Local structural defects<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">water can still seep out through these channels.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Therefore, it can be simply understood as:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>PP material itself has good water resistance, while whether a PP printed part is truly waterproof depends on the material, printing process and part structure.<\/strong><\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Material level: What is the relationship between PP and water?<\/strong><strong><\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">PP has very low water absorption.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">This means that in general humid environments, PP printed parts usually do not show significant dimensional changes from absorbing large amounts of water, as some more hygroscopic materials might.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">For applications that need to contact water, this is an important advantage.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">For example:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Water containers<\/li>\n\n\n\n<li>floats<\/li>\n\n\n\n<li>Bathroom Fittings<\/li>\n\n\n\n<li>Water-contact structural parts<\/li>\n\n\n\n<li>Functional parts in humid environments<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">However, it is necessary to distinguish between<strong>Low water absorption<\/strong>compared with<strong>finished-part leak prevention<\/strong>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Low water absorption means PP itself does not easily absorb moisture; but whether a 3D-printed container leaks also depends on whether its printed structure is dense enough.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Therefore, material data cannot directly replace the waterproof testing of the finished product.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>What happens if PP is immersed in water for a long time?<\/strong><strong><\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">PP has good resistance to water; long-term contact with water usually does not cause significant material structure changes from water absorption, as can happen with some hydrolytically prone materials.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">But the specific performance still depends on:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Water temperature<\/li>\n\n\n\n<li>Soaking time<\/li>\n\n\n\n<li>Material formulation<\/li>\n\n\n\n<li>Whether other chemical media are present<\/li>\n\n\n\n<li>The structure of the printed part itself<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">If the actual application involves hot water, cleaning agents or other liquids, testing should be performed against the actual use conditions, rather than judging solely based on PP\u00e2\u0080\u0099s general water resistance.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">For example,<strong>100\u00c2\u00b0C boiling water environment<\/strong>already constitutes a more severe temperature condition and should be verified separately.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Why do PP printed parts leak?<\/strong><strong><\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Water moves along the path of least resistance within the printed part.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">For FDM printed parts, common potential leakage locations include:<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Inter-layer bonding zones<\/strong><strong><\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">If adjacent printed layers do not form sufficient fusion, tiny channels may be left behind.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">These channels may not be easy to spot with the naked eye, but can leak under sustained water pressure.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Corners and local structures<\/strong><strong><\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">At sharp corners, thin-wall regions or locations with large extrusion variations, local material shortage may occur.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Top and bottom surfaces<\/strong><strong><\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">If the top or bottom layers contain pores, they can also become paths for water to seep out.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Low-density infill structures<\/strong><strong><\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">For container-type parts, if a low infill density is used internally, the internal structure may contain a large number of voids.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Therefore,<strong>A printed part that looks &#8220;thick-walled&#8221; does not necessarily mean the entire structure is completely dense.<\/strong><\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Material waterproofing and part waterproofing are two different things<\/strong><strong><\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">This is one of the most important distinctions when understanding 3D-printed waterproof performance.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">It can be divided into two levels:<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Material level<\/strong><strong><\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Focus on:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Does PP easily absorb water?<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">PP has very low water absorption, so it has an advantage in this regard.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Part level<\/strong><strong><\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Focus on:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Can water seep out through the internal channels of the printed part?<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">This depends on:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Wall thickness<\/li>\n\n\n\n<li>Number of wall lines<\/li>\n\n\n\n<li>Extrusion state<\/li>\n\n\n\n<li>Interlayer bonding<\/li>\n\n\n\n<li>Top and bottom layer thickness<\/li>\n\n\n\n<li>Print orientation<\/li>\n\n\n\n<li>Part structure<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Therefore, a PP printed part can achieve very good leak resistance, but it cannot be considered to have complete waterproof capability simply because it uses PP.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>How to make PP printed parts less likely to leak?<\/strong><strong><\/strong><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>1. Prioritize increasing the number of wall lines<\/strong><strong><\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">For container-type parts, increasing the outer walls is usually more direct than simply raising the internal infill density.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Because it is the continuous outer wall structure that actually provides the leak-resistant function.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Depending on actual needs, you can increase:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Number of wall lines<\/li>\n\n\n\n<li>Outer wall thickness<\/li>\n\n\n\n<li>Top layer thickness<\/li>\n\n\n\n<li>Bottom layer thickness<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>2. Ensure sufficient extrusion and good inter-layer fusion<\/strong><strong><\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Under-extrusion can create gaps between adjacent lines.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Therefore, adjustments should be made according to the specific PP material:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Nozzle temperature<\/li>\n\n\n\n<li>Flow rate<\/li>\n\n\n\n<li>Print speed<\/li>\n\n\n\n<li>Floor height<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">The goal is to allow adjacent print paths to form a sufficiently stable fusion.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">But higher parameters are not always better; excessively high temperatures or over-extrusion can also bring other printing problems.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>3. Optimize the container bottom and corners<\/strong><strong><\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">For parts such as water tanks, cups and containers, unnecessary sharp corners can be reduced.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Reasonable fillet design helps reduce local stress concentration and also facilitates the formation of a more continuous print path.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>4. Perform pore sealing when necessary<\/strong><strong><\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">For parts with high leak-prevention requirements, additional surface pore sealing or coating treatment can be considered.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">However, one characteristic of PP is that<strong>surface energy is low<\/strong>, ordinary coatings and adhesives may have difficulty adhering.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Therefore, if a coating is used for sealing, the following should be verified in advance:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Adhesion of the coating to PP<\/li>\n\n\n\n<li>Water resistance of the coating<\/li>\n\n\n\n<li>Temperature resistance of the coating<\/li>\n\n\n\n<li>Long-term stability under actual use conditions<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Do not assume that any coating can be directly used on PP.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Splash resistance and true leak-proofing are not the same standard<\/strong><strong><\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">&#8220;Waterproof&#8221; can actually correspond to different usage requirements.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Splash resistance<\/strong><strong><\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">For example:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Rain<\/li>\n\n\n\n<li>Water droplets<\/li>\n\n\n\n<li>Occasional water contact<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Such applications usually do not need to withstand sustained water pressure.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Holding liquid without leaking<\/strong><strong><\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">For example:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Water cups<\/li>\n\n\n\n<li>Water tanks<\/li>\n\n\n\n<li>Water storage containers<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Such parts need to hold liquid internally for a long time, and usually require higher structural density.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Sustained water pressure<\/strong><strong><\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">For example:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Pipe components<\/li>\n\n\n\n<li>Pressurized containers<\/li>\n\n\n\n<li>Pump-related structures<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Such applications have higher requirements for the sealing and structural strength of printed parts, and require more rigorous testing.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Therefore, before judging whether a PP printed part is &#8220;waterproof,&#8221; it is best to first clarify which category the actual application belongs to.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>How to test the waterproof performance of PP printed parts?<\/strong><strong><\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The simplest method is to perform a<strong>water-filling test<\/strong>.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Step 1: Prepare the printed part<\/strong><strong><\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Print the complete container or actual-use part.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">During testing, record:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Material grade<\/li>\n\n\n\n<li>Nozzle temperature<\/li>\n\n\n\n<li>Floor height<\/li>\n\n\n\n<li>Number of wall lines<\/li>\n\n\n\n<li>Fill rate<\/li>\n\n\n\n<li>Print orientation<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Step 2: Add a fixed volume of water<\/strong><strong><\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Fill the container with a certain amount of water and record the start time.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Step 3: Let it stand and observe<\/strong><strong><\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Depending on the actual application requirements, a fixed test time can be set, for example:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>24 hours<\/li>\n\n\n\n<li>48 hours<\/li>\n\n\n\n<li>72 hours<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Observe whether water marks appear on the outer wall, bottom and connection positions.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Step 4: Check mass change<\/strong><strong><\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">If a more quantitative test is needed, the container or liquid can be weighed before and after the test to help determine whether slow leakage exists.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">For higher-requirement applications, a sealed test under specified pressure can also be performed.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Water-contact parts can also undergo a cold-hot cycle test<\/strong><strong><\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">If the part will experience temperature changes during actual use, a cold-hot cycle immersion test can be further performed.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">For example:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Room temperature \u00e2\u0086\u0092 Hot water \u00e2\u0086\u0092 Cooling \u00e2\u0086\u0092 Room temperature<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">After repeating multiple cycles, check:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>whether cracks appear<\/li>\n\n\n\n<li>Whether deformation occurs<\/li>\n\n\n\n<li>Whether leakage appears<\/li>\n\n\n\n<li>Whether inter-layer damage occurs<\/li>\n\n\n\n<li>Whether the sealing positions show problems<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Temperature changes bring thermal expansion and contraction as well as internal stress, so a single static immersion test may not cover all actual usage situations.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Can PP printed parts be used directly in long-term water environments?<\/strong><strong><\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">This needs to be judged based on the specific application.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">If it is only:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>humid environments<\/li>\n\n\n\n<li>Occasional water contact<\/li>\n\n\n\n<li>Short-term immersion<\/li>\n\n\n\n<li>Ordinary cold-water environment<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">PP usually has good material adaptability.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">But if it involves:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Hot water<\/li>\n\n\n\n<li>Long-term water pressure<\/li>\n\n\n\n<li>Chemical cleaning agents<\/li>\n\n\n\n<li>Long-term outdoor use<\/li>\n\n\n\n<li>Drinking water or food contact<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">additional verification should be performed for the actual conditions.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Especially for food-contact and drinking-water applications,<strong>you cannot directly assume that the final 3D printed part automatically meets the corresponding regulations or safety requirements just because the base material is PP<\/strong>. This also involves material formulation, additives, printing equipment, nozzles, contamination control, surface condition and specific regulatory requirements.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Summary<\/strong><strong><\/strong><\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li>PP itself has very low water absorption and offers good stability in humid and general water environments.<\/li>\n\n\n\n<li><strong>Material water resistance \u00e2\u0089\u00a0 a 3D printed part is definitely leak-proof.<\/strong><\/li>\n\n\n\n<li>The leak-proof performance of printed parts is mainly affected by inter-layer bonding, wall thickness, number of wall lines, extrusion state and structural design.<\/li>\n\n\n\n<li>Increasing wall lines, ensuring sufficient extrusion, and optimizing bottom and corner structures can help improve leak resistance.<\/li>\n\n\n\n<li>PP\u00e2\u0080\u0099s low surface energy increases coating adhesion difficulty; pore sealing or coating should be verified in advance.<\/li>\n\n\n\n<li>Splash resistance, holding liquid without leaking and withstanding sustained water pressure are different levels of waterproofing requirements.<\/li>\n\n\n\n<li>The most reliable way to judge is to<strong>perform actual water-filling, immersion or pressure tests on the final printed part<\/strong>.<\/li>\n\n\n\n<li>If the application involves hot water, long-term water pressure, chemical media or food\/drinking-water contact, verification should be performed for the specific use conditions.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n<div id=\"rank-math-faq\" class=\"rank-math-block\">\n<div class=\"rank-math-list\">\n<div id=\"faq-question-polive-3512-1\" class=\"rank-math-list-item\">\n<h3 class=\"rank-math-question\">Are PP Printed Parts Waterproof?<\/h3>\n<div class=\"rank-math-answer\">\n\n<p>At the material level, PP absorbs almost no water and stays dimensionally stable in humid or wet environments. Whether the finished part actually holds water is a different question \u2014 the interlayer gaps of FDM are what matter.<\/p>\n\n<\/div>\n<\/div>\n<div id=\"faq-question-polive-3512-2\" class=\"rank-math-list-item\">\n<h3 class=\"rank-math-question\">Why Does a PP Container Leak?<\/h3>\n<div class=\"rank-math-answer\">\n\n<p>Leaks usually start at interlayer bonding zones, corners and local features, top and bottom surfaces, and low-infill areas \u2014 not because the material is damaged by water. Greater wall thickness and rounded transitions noticeably reduce these weak points.<\/p>\n\n<\/div>\n<\/div>\n<div id=\"faq-question-polive-3512-3\" class=\"rank-math-list-item\">\n<h3 class=\"rank-math-question\">Is Splash Resistance the Same as Being Truly Watertight?<\/h3>\n<div class=\"rank-math-answer\">\n\n<p>No. Splash resistance only requires the surface to hold up; long-term liquid storage or pressurised use needs a real liquid leak test. Run the test at the actual fill level, for the actual duration, and with pressure if that is how it will be used.<\/p>\n\n<\/div>\n<\/div>\n<div id=\"faq-question-polive-3512-4\" class=\"rank-math-list-item\">\n<h3 class=\"rank-math-question\">How Do You Make Water-Contact Parts Less Prone to Leaking?<\/h3>\n<div class=\"rank-math-answer\">\n\n<p>Increase wall thickness, improve perimeter sealing, avoid sharp corners and abrupt wall-thickness changes, and keep load directions away from interlayer bonding planes. Uniform wall thickness and rounded transitions during printing also help reduce warping.<\/p>\n\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n\n\n<h2 class=\"wp-block-heading\"><strong>Related Reading<\/strong><strong><\/strong><\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/www.polive3d.com\/en\/3d-%e6%89%93%e5%8d%b0%e8%83%bd%e5%81%9a%e6%b6%89%e6%b0%b4%e9%9b%b6%e4%bb%b6%e5%90%97%ef%bc%9f%e6%b0%b4%e7%ae%b1%e3%80%81%e6%b5%ae%e4%bd%93%e4%b8%8e%e5%8d%ab%e6%b5%b4%e9%85%8d%e4%bb%b6\/\" data-type=\"post\" data-id=\"3657\">Can 3D Printing Handle Parts That Touch Water? Tanks, Floats and Bathroom Fittings<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/www.polive3d.com\/en\/3d-%e6%89%93%e5%8d%b0%e8%83%bd%e5%81%9a%e5%8c%96%e5%b7%a5%e5%ae%b9%e5%99%a8%e5%92%8c%e7%ae%a1%e9%81%93%e4%bb%b6%e5%90%97%ef%bc%9f%e8%80%90%e8%85%90%e8%9a%80%e9%9b%b6%e4%bb%b6%e6%8e%a2%e7%b4%a2\/\" data-type=\"post\" data-id=\"3616\">Can 3D printing be used for chemical vessels and piping components? Exploring corrosion-resistant parts<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/www.polive3d.com\/en\/3393\/\" data-type=\"post\" data-id=\"3393\">Does PP Absorb Water? Moisture Absorption of PP Filament and Prints<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/www.polive3d.com\/en\/pp-3d-%e6%89%93%e5%8d%b0%e4%bb%b6%e8%83%bd%e8%a3%85%e5%bc%80%e6%b0%b4%e5%90%97%ef%bc%9fpolive-pppro-100c-%e6%b2%b8%e6%b0%b4%e6%b5%8b%e8%af%95\/\" data-type=\"post\" data-id=\"2706\">Why Does PP Have Good Heat Resistance?<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/www.polive3d.com\/en\/pp-%e6%89%93%e5%8d%b0%e4%bb%b6%e8%83%bd%e6%89%bf%e5%8f%97%e5%a4%9a%e5%b0%91%e6%b8%a9%e5%ba%a6%ef%bc%9fpp-%e7%9a%84%e8%80%90%e7%83%ad%e8%a1%a8%e7%8e%b0\/\" data-type=\"post\" data-id=\"3502\">How Much Temperature Can PP Prints Withstand? PP&#8217;s Heat-Resistance Performance<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/www.polive3d.com\/en\/pp-%e8%80%90%e5%8c%96%e5%ad%a6%e6%80%a7%e6%80%8e%e4%b9%88%e6%a0%b7%ef%bc%9f%e4%ba%86%e8%a7%a3-pp-3d-%e6%89%93%e5%8d%b0%e4%bb%b6%e7%9a%84%e5%8c%96%e5%ad%a6%e8%80%90%e5%8f%97%e6%80%a7\/\" data-type=\"post\" data-id=\"2942\">Which Chemicals Can PP Withstand?<\/a><\/li>\n\n\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>","protected":false},"excerpt":{"rendered":"<p>This article analyzes the performance of PP material in water environments, pointing out that although its water absorption is low, whether a printed part is waterproof depends on inter-layer bonding and structure. Material waterproofing is not equal to part waterproofing, and the causes of leakage are analyzed.<\/p>","protected":false},"author":1,"featured_media":3514,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[35],"tags":[205,67,88,206,204,203],"class_list":["post-3512","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-35","tag-polypropylene-water-resistance","tag-pppro-2","tag-pp","infinite-scroll-item","generate-columns","tablet-grid-50","mobile-grid-100","grid-parent","grid-33"],"_links":{"self":[{"href":"https:\/\/www.polive3d.com\/en\/wp-json\/wp\/v2\/posts\/3512","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.polive3d.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.polive3d.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.polive3d.com\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.polive3d.com\/en\/wp-json\/wp\/v2\/comments?post=3512"}],"version-history":[{"count":4,"href":"https:\/\/www.polive3d.com\/en\/wp-json\/wp\/v2\/posts\/3512\/revisions"}],"predecessor-version":[{"id":4012,"href":"https:\/\/www.polive3d.com\/en\/wp-json\/wp\/v2\/posts\/3512\/revisions\/4012"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.polive3d.com\/en\/wp-json\/wp\/v2\/media\/3514"}],"wp:attachment":[{"href":"https:\/\/www.polive3d.com\/en\/wp-json\/wp\/v2\/media?parent=3512"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.polive3d.com\/en\/wp-json\/wp\/v2\/categories?post=3512"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.polive3d.com\/en\/wp-json\/wp\/v2\/tags?post=3512"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}